MIL-PRF-53015B
3.6.2.1 Dissimilar metals. Dissimilar metals shall not be used in intimate contact without
suitable protection to prevent galvanic corrosion.
3.6.3 Government loaned property. Unless otherwise specified (see 6.2), the following
property, in the quantities indicated, will be loaned or made available by the Government at a
location specified by the contracting officer (see 6.4).
Quantity
Government loaned property for type I kit test
a. Hoseline, collapsible, high pressure, 6-inch by 500 feet, (MIL-PRF-370)
3
b. Hose clamps, (part of MIL-PRF-53013)
3
Government loaned property for type II kit test
Quantity
a. Hoseline, collapsible, high pressure, 4-inch by 500 feet, (MIL-PRF-370)
3
b. Hose clamps, (part of MIL-PRF-52343)
3
4. VERIFICATION
4.1 Classification of inspection. The inspection requirements specified herein are
classified as follows:
a. First article inspection (see 4.2).
b. Conformance inspection (see 4.3).
4.2 First article inspection. The first article inspection shall be performed on a minimum
of one complete kit (see 3.2 and 6.2). This inspection shall include the examinations of 4.4 and
the tests of 4.5. Nonconformance to any specified requirement, the failure of any test, or the
presence of one or more defects shall be cause for rejection.
4.3 Conformance inspection. The conformance inspection, performed on all production
kits, shall include the identified examinations of 4.4. Nonconformance to any specified
requirement or the presence of one or more defects shall be cause for rejection.
4.4 Examination. The type I and type II hoseline displacement and evacuation kits shall
be examined for defects as specified in table II. Presence of one or more defects shall be cause
for rejection.
4.5 Tests.
4.5.1 Functional test. For testing, a government furnished 1500-foot hoseline assembly
(three 500 foot sections with hose clamps) shall be laid out with the discharge end at a slightly
higher elevation than the inlet. The layout shall provide a hydrostatic head of two feet,
minimum, for the displacement procedure. The inlet of the hoseline assembly shall be sealed
with a pipe cap, and filled with water from the discharge end. Three hose clamps shall be
installed and tightened at the following positions: