MIL-PRF-53015B
3.3.7 Grooved-end pipe cap. The grooved-end pipe caps in accordance with A-A-52592
shall be a 6-inch size for the type I kit, and 4-inch for the type II kit.
3.3.8 Performance requirements. When properly installed and operating from a
compressed air source of 80 psi at 110 cfm, the displacement of liquid in a 1000 foot section of
hoseline shall be completed within 30 minutes for a type I kit, and 15 minutes for a type II kit
(see 4.5.1.1). The evacuation and collapse of a 1000 foot section of hoseline shall be completed
within 30 minutes for a type I kit and 15 minutes for a type II kit (see 4.5.1.2). The displacement
and evacuation of the hoseline shall be completed without damage or degradation of hoseline
components.
3.4 Environmental.
3.4.1 Storage. The components of the kit shall withstand storage at temperature
extremes of -45 °F to 165 °F, at any relative humidity (see 4.5.2).
3.4.2 Operation. The components of the kit shall be capable of operating, as specified
herein, at any temperature between 25 °F and 120 °F, at any relative humidity (see 4.5.2).
3.5 Interface. The kits shall be capable of interfacing and functioning with hoselines in
accordance with MIL-PRF-370 (see 3.6.3).
3.6 Sustainment.
3.6.1 Chest. A rugged, lightweight chest capable of containing all kit components shall
be provided. The chest shall not exceed 22.00 inches in height and have a cover, cover securing
devices, and handles capable of supporting the chest with all components. The placement and
quantity of handles shall be consistent with an individual lift capability of 40 pounds. The chest
shall have bins, cradles, or blocking for the kit components, to prevent uncontrolled movement
or damage, and a reasonably balanced weight distribution for handling.
3.6.1.1 Chest color. The external finish color shall be as specified (see 6.2).
3.6.1.2 Identification marking. Kit identification markings shall be applied to the
external surface of the chest as specified (see 6.2). A plan indicating component placement
within the chest shall be secured to the inside of the chest cover, visible to the operator.
3.6.2 Materials. The contractor shall select materials capable of meeting all the
operational requirements, in any of the environmental conditions, specified herein. Pipe and pipe
fittings shall be of a single durable, rigid, lightweight, corrosion resistant, non-magnetic material,
with a minimum tensile strength of 30,000 psi, suitable to the application and compatible with
aluminum. The components incorporated into the kit may be newly fabricated from recovered
materials to the maximum extent practicable, provided they meet all other requirements of this
specification. Used, rebuilt, or remanufactured components shall not be incorporated into the kit.
5