MIL-PRF-12732F
113.
Castings contain blowholes, porosity shrinkage, or cracks (see 3.20.2). 1/
114.
Units not completely drained for delivery (see 4.5.2.3.2).
Minor:
201. Identification or other markings, or operating and safety instructions incorrect,
missing, or illegible (see 3.16 and 3.17).
202. Presence of buckling, kinks, scribe lines, or punch marks on complete members
(see 3.20.1).
203. Sharp edges, slivers, burrs, or projections on finished surfaces (see 3.20.1).
NOTES: 1/ Examination shall be made prior to painting.
4.5.2 Tests.
4.5.2.1 Hydrostatic. The unit shall be subjected to a hydrostatic test pressure of 100 psig
and examined for leaks. Any pipe, tubing or fitting leak, or damage to any component shall
constitute failure of this test.
4.5.2.2 Torque. The hypo chlorinator shall be disconnected from the water meter and the
torque required to turn the shaft of the hypchlorinator shall be determined with a torque wrench.
Measured torque greater than 8 inch-ounces shall constitute failure of this test.
4.5.2.3 Performance.
4.5.2.3.1 Test conditions. The unit shall be connected to test equipment as shown on
figure 1 and tested under the conditions given in table I and in accordance with the test procedure
outlined in 4.5.2.3.2. Data shall be recorded on a test data sheet as shown on figure 2. One data
sheet shall be furnished with each unit. The test equipment shall not be limited to that shown on
figure 1.