MIL-M-52372B
4.3 Quality conformance inspection.
Sampling for examination shall be in accordance
4.3.1 Sampling.
with MIL-STD-105.
4.3.2 Examination. Samples selected in accordance with 4.3.1 shall
be examined as specified in 4.4.1. AQL shall be 2.5 percent defective
for major defects and 6.5 percent defective for minor defects.
4.4 Inspection Procedure.
4.4.1 Examination. Measures shall be examined as specified herein,
for the following defects:
Major
101.
Dimensions not as specified on figures.
102.
Materials not as specified on figures.
Tolerances not as specified on figures.
103.
Radius not as specified on figures.
104.
Graduation lines not as specified on figures.
105.
106.
Workmanship not as specified.
Minor
201.
Markings not as specified.
202,
Identification missing, incomplete, or illegible.
4.5 Inspection of packaging.
4.5.1 Quality conformance inspection of pack.
4.5.1.1 Unit of product. For the purpose of inspection, a completely
processed pack prepared for shipment shall be considered a unit of
product.
Sampling for examination shall be in accordance
4.5.1.2 Sampling.
with MIL-STD-105.
4.5.1.3 Examination. Samples selected in accordance with 4.5.1.2
shall be examined for the following defects. AQL shall be 2.5 percent
defective.